null
Toggle menu

Kubota Portable Diesel Generator—Portable Workhorse for Any Application

Written By: MJ Logan

Four Kubota Lowboy Portable Diesel Generators with a thunderstorm in the background

Kubota manufactures a wide range of construction and agricultural products including the Kubota Diesel Generator. Powered by a liquid-cooled diesel engine, the Kubota Lowboy Generator has a reputation for long life and durability.

Portable Diesel Generators

The Lowboy II GL Series incorporates 2- and 3-cylinder EPA Tier 4 Final engines for environmentally friendly and fuel-efficient diesel generators in a compact low-body design. The vertical engine and direct-drive coupling to the alternator and fan reduce overall height and improve efficiency.

Lowboy II Portable Diesel Generators are rated for portable, prime, and standby power. Two-wire start allows the generator to operate as a standby generator in conjunction with an automatic transfer switch (ATS.)

About Kubota Corporation Generators

Kubota Generator

A technician works on a Kubota Generator EngineKubota. “For Earth. For Life.”

Kubota is a worldwide leader committed to protecting the environment while manufacturing products for a greener world by improving energy efficiency, reducing waste, and expanding their use of renewable energy.

A variety of Kubota Generator uses include rural or off-grid backup power, construction sites, remote offices, events, and mobile applications. Equipped for forklift carry or a crane lift, the generators can go almost anywhere while the low profile reduces the space required for placement.

Design features include options for use with extension cords, generator cords, and terminal connections. Two-wire start capability allows use with an automatic transfer switch. Average noise levels at 21 feet measure lower than most gasoline and diesel-powered portables in the same class. Efficient engine design and Kubota's original E-TVCS combustion system reduce HC and CO emissions. The Lowboy II Series generators meet U.S Environmental Protection Agency and California Air Resources Board Tier 4 Final emissions requirements.

Kubota Diesel Generators for Sale

Kubota Portable Diesel Generator

A Technician Performs Preventative Maintenance on a Kubota Lowboy Pro 14kW GeneratorPortable in the sense that the design allows placement where you need it today, and someplace else tomorrow. The Kubota Diesel Generators come equipped for placement with a lift hook or forklift. The GL7000 weighs 518 pounds dry and the GL14000 comes in at just over 900 pounds.

Each model comes with appropriate receptacles and a terminal option. Receptacles allow use with extension or generator cords. Terminal connections provide connections to a circuit breaker panel as a prime power source or to a transfer switch—either manual or automatic.

The liquid-cooled diesel engine stays cooler during extended operation in hot weather. Cooler operation means a longer engine life. Operate the diesel generator all day on construction sites or throughout an event. A 200-hour maintenance interval means it can handle a month of 8-hour shifts between oil changes, or a whole week of 24/7 operation. Single-side maintenance for easy oil and filter changes.

Put the Kubota Portable Generator on a trailer and take it wherever you need reliable, clean power in any environment.

Kubota Generators

Kubota Lowboy Generator

Kubota Lowboy Portable Diesel Generator at a construction site.Kubota reduced the height of the Lowboy GL series Generator by using a vertical diesel engine direct coupled to the alternator at the rear of the engine. At the front, a pulley-belt arrangement drives the fan and water pump, and the battery charging alternator.

A single panel on the side of the generator provides easy access for all maintenance requirements. Through the access panel are the oil gauge, oil filter, oil fill tube, fuel filter, water tank, battery, and air cleaner. Kubota includes engine oil and coolant drain extensions to simplify and assist with on-time oil and coolant changes. The generator shuts down automatically for low oil conditions or high coolant temperatures.

The Norwall Kubota Lowboy Product Line includes three models: the GL14000, GL11000, and GL7000. Design features include an integrated fuel tank and a 2 or 3-cylinder diesel engine. Outlets have their own circuit breakers and the generator has a main breaker to protect from diesel generator overload.

 

Control PanelOperation Panel
Volts – Amps – Frequency MeterHour Meter
Ammeter Selector SwitchTachometer
Voltage Adjusting DialFuel Gauge
Available Output Meter 
Voltage Indicator Light 
Emergency Stop 

Kubota Lowboy Generator

Kubota GL14000 Lowboy Diesel Generator

A Kubota Diesel Engine D902 Powers the GL14000 Portable Diesel GeneratorPowered by a Kubota D902 3-cylinder water-cooled diesel with indirect injection and rated for 12kW and a maximum surge capacity of 14kW, the GL14000 120/240-Volt 60 Hertz single-phase generator has an integrated 9.6-gallon fuel tank for up to 15 hours run time at 25 percent load. The GL14000 includes Engine Shutdown for Low Oil Pressure, High Coolant Temps, Improper Charging, or High Engine Speed.

Meets EPA Tier 4 Final and CARB Standards

Spill Containment: 186 Percent of the combined fuel and coolant capacity. Fuel containment engine shutdown.

OutletsCircuit Breakers
3-Wire Output TerminalsMain Breaker
120/240V-50A Twist Lock2-Pole 50 Amp Breaker
120V-20A GFCI x 2 (4 receptacles)GFCI Breakers

 

Kubota Lowboy GL14000 Portable Diesel Generator

Kubota GL11000 Lowboy Diesel Generator

A Kubota Diesel Engine D722 Powers the GL11000 Portable Diesel GeneratorKubota rates the GL11000 at 11kW standby power and 10kW prime power. This is a single phase, 120/240-Volt Generator rated at 83.3/41.7 amps. The D722 3-cylinder engine vertical liquid-cooled engine operates up to 12.7 hours at 25 percent load on the 7.4-gallon fuel tank.

Emergency Stop for Low Oil Pressure and High Coolant Temperature.

Meets EPA Tier 4 Final and CARB Emission Standards

OutletsCircuit Breakers
CS 6369 120/240V-50AMain Circuit Breaker
L5-30R 120-Volt 30 Amp1 - 30-Amp 2 Pole Breaker
L6-30R 240-Volt 30 amp1 - 30-Amp 2 Pole Breaker
120V-20A GFCI x 2 (4 receptacles)2 - GFCI Outlet Breakers

Kubota GL11000 Portable Diesel Generator

Kubota Lowboy GL7000 Lowboy Diesel Generator

A Kubota Z482 Two-Cylinder Diesel Engine Powers the GL7000 Portable GeneratorKubota rated the GL7000 for7kW standby power and 6.5kW prime power. The GL7000 is a 120/240-Volt Single Phase Generator rated at 54.2/27.1 amps. A Z482 vertical liquid-cooled engine runs up to 20 hours on a single 7.4-gallon fuel tank.

Emergency Stop for Low Oil Pressure and High Coolant Temperature.

Meets EPA Tier 4 Final and CARB Emission Standards.

OutletsCircuit Breakers
L14-30R 125/240V 30A1 - 30-Amp 2 Pole Breaker
L5-30R 120-Volt 30 Amp1 - 30-Amp 2 Pole Breaker
L6-30R 240-Volt 30 amp1 - 30-Amp 2 Pole Breaker
120V-20A GFCI 2 receptacles1 - GFCI Outlet Breakers

Kubota GL7000 Portable Diesel Generator

 

POWER EXPERT

menu Article Content

Back to Top

menu Article Content

close
Back to Top