Generac Power Systems XG04045CNAC Details and Specifications
Generac 40kW Generator
40kW NG or LP Configurable for 208, 240, or 480 Volts EPA/SCAQMD Certified Single Side Maintenance
The Generac 40 kW Generator adds well-known features to new improvements with the Protector XG series. The 40kW XG04045 has a 4.5 Liter engine that runs at 1800 RPM under load and 1200 RPM during self test or at low idle. A NEW Power Zone 420 Controller brings the latest in technology with additional functionality and more features than ever before, including the ability to select the fuel type at the controller without any other modifications. This controller is NFPA 110 capable.
XG 3-Phase generators have a 12-lead alternator hardwired to a terminal block. A Voltage Control Cartridge (VCC) makes the necessary connections for 208 Volt, 240 Volt, or 480 Volt 3 Phase current. The Generac configures 3-Phase Generators at the factory with a 208-Volt VCC. At Installation, the installer can replace the 208 VCC with a 240 or 480-Volt VCC.
Important: Use with an RTS 3-Phase Transfer Kit Requires a 3-Phase Voltage Sensing Kit
- 120/208 Volts 3 Phase ("G" Voltage) order Voltage Sense Kit 7411
- 120/240 Volts 3 Phase ("J" Voltage) order Voltage Sense Kit 7411
- 277/480 Volts 3 Phase ("K" Voltage) order Voltage Sense Kit 7412
40kW Standard Features
The new XG series carries forward the familiar features found in earlier models like quiet operation. A Generac 4.5-liter engine beats the competition on fuel efficiency for comparable generator models that produce less power. The 40kW XG maintains its UL-2200 listing along with the EPA and SCAQMD Certification. An aluminum enclosure guards the generator against corrosion. Protected by a Generac 5-year/2000-hour limited warranty.
Generac didn’t stop with the features that Protector Series users came to expect.
New 40 kW Generator Features
New Electro-Galvanized base frame components prevent rust and corrosion. Single-side regular maintenance make service fast and easy through the front, key-locked panel. Change or check the oil, oil filter, and air filter; check or change the coolant; replace the spark plugs or check the battery.
Fuel setup is made easier than ever through the controller. Set the 40 kW generator fuel type in the controller—no other adjustments are necessary.
The generator exercises at 1200 RPM for a peaceful 58 dBA noise level and 64 dBA under normal load. The PowerZone 410 Controller has more features and more capability than ever before, including an overload control that eliminates the need for a circuit breaker.
Cellular connectivity is standard for Mobile Link & Fleet.